    目的?建立并优化甲状腺功能检测项目自动审核系统。方法?依据CLSI AUTO10-A和CLSI AUTO15,基于AptioTM生化免疫自动化流水线中间件软件进行甲状腺功能检验项目自动审核程序建立及验证,采用Delta check 大数据智能分析系统进行特定学科人群统计分析及自动审核规则优化。结果?细化自动审核范围、调整Delta check 值以及增加甲状腺功能指标组合模式判断规则后,促甲状腺激素(TSH)、游离甲状腺素(FT4)、游离三碘甲腺原氨酸(FT3)、总甲状腺素(TT4)、总三碘甲腺原氨酸(TT3)的平均通过率都在90%以上,而抗甲状腺球蛋白抗体(A-TG)和抗甲状腺过氧化物酶抗体(A-TPO)的平均通过率在70%以上,整体较之前升高了7%~17%。甲状腺功能检验结果自动审核平均通过率从84.68%上升至94.45%,升高幅度达9.77%。实验室内标本周转时间(TAT)中位数从92 min降至78 min,缩短15.2%,自动审核报告TAT 中位数从70~85 min下降至60~75 min。检验报告的差错率从0.096‰(5/51 976)下降至0.000‰(0/154 282),报告的审核时效和准确性明显提高。结论?自动审核系统的建立、验证与优化,可以减轻工作强度,缩短TAT,降低风险并提高工作效率。

    Abstract:

    Objective?To establish and optimize an autoverification system for the test results of thyroid function.Methods?According to AUTO10-A and AUTO15 approved by Clinical and Laboratory Standards Institute(CLSI),the autoverification system for the test results of thyroid function was established and verified based on AptioTM?automation platform.The Delta Check intelligence systemwas used for statistical analysis of specific subjects and optimize autoverification rules.Results?After refining the range of autoverification,adjusting the delta check value and adding the judgment rule of thyroid function index combination mode,the average autoverification rates of TSH,FT4,FT3,TT4 and TT3 were above 90%,while the average autoverification rates of A-TG and A-TPO were above 70%,which were higher than those of previous results for 7% to 17%.The average autoverification rate of the reports increased from 84.68% to 94.45% with increase rate of 9.77%.The median turnaround time(TAT)in the laboratory was shortened by 15.2% from 92 to 78 minutes.The median TAT of autoverification for reports decreased from 70-85 minutes to 60-75 minutes.The error rate of reports decreased from 0.096 ‰(5/51 976)to 0(0/154 282),which significantly improved the autoverification effectiveness and accuracy of the test reports.Conclusion?The establishment,verification and optimization of autoverification system could reduce work intensity,decrease TAT,reduce risks and effectively improve work efficiency and ensure the test quality.

    参考文献
    相似文献
    引证文献
引用本文

胡婷,王伟佳,陈康,索明环,胡耀宗,陈颖,王霞,田原,萧金丽.甲状腺功能检测项目自动审核系统的建立与优化[J].临床检验杂志,2021,39(7):530-533

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2020-11-23
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2021-09-09
  • 出版日期: 2021-07-28
您是第位访问者  苏ICP备12051282号-1
主管单位:江苏省医学会  出版单位:临床检验杂志
单位地址:江苏省南京市中央路42号  邮编:210008
电话:025-83620683 E-MAIL:lcjyzz@163.com
技术支持:北京勤云科技发展有限公司